Comparative Study of Selected Respiratory Cardio Variables Of-Household and Non Household Wives of Kashmir Division

Dar NA

Published on: 2022-07-18

Abstract

The Study Was Conducted To Know And Then Compare The Respiratory Cardio Fitness Variables Of Household And Non-Household Wives Of Kashmir Division. A total of sixty (60) subjects, that is 30 subjects were taken ashouseholf wives and 30 as non household wives of Kashmir division and all of them were randomly selected for above discussed study for verification and comparison. The household and non household wives were included research study by using sampling technique called as simple random sampling. The subjects for the study were between 30-40 years old. To analyze the respiratory cardio variables such as Hemoglobin content, Exhale tendency resting heart rate and maxim oxygen intake capacity vo2max. Of the subjects from houshousehold and non household wives of Kashmir Division different testing kits and equipment were used for obtaining the scores related to various variables included in the study. Haemometer , hcl diluted water blade or needle were used for measuring Haemoglobin content of each subject. Peak flow meter was used for measuring Exhale capacity of each individual with three trails . A digital Stop watch was used for recording resting Heart Rate per minute count. Vo2max. Bench stop watch metronome were used knowing the Cardiovascular Endurance of both houshousehold and non household wives of Kashmir DivisionAfter the data for all the variables from both the groups were recorded in separate columns Then the analysis of data was carried out by mean standard deviation and by using statistical technique ‘t’- test in order to find out the significance difference of selected Respiratory Cardio variables between household and non household wives of Kashmir Division and the level of significance as per rules (p<0.05) was used. The obtained means and calculated standard deviation ofselected respiratory cardio variables of household wives of Kashmir Divisionfor the mean and standard deviation of Hemoglobin amount is ( 11.82 ± 1.07 ), the mean and standard deviation of Exhale capacity is respectively ( 397.4 ± 64.91) , the mean and standard deviation of Resting heart rate is ( 76.68 ± 5.09) and the mean and standard deviation VO2 Max is ( 57.24 ± 7.28 ) and the calculated means and standard deviation ofselected respiratory cardio variables of non household wives under keen observation was recorded viz. the mean and standard deviation of Hemoglobin amount is (12.87± 2.91), the average and standard deviation of Exhale capacity is (449 ± 64.39), the mean and standard deviation of Resting heart rate is (72.84 ± 5.25) and the mean and standard deviation of VO2 Max is (60.66 ± 5.52). Hence the non household wives were found with sound and good respiratory cardio capacities as compared to household wives the difference is wide and the reason behind may be due exposure to smoke from traditional chulas while cooking and dust as compared to non-household wives which might have resulted in poor performance of respiratory and cardio system of the household wives research also has shown that any type of pollutant is hazardous for human which directly or indirectly affects the respiratory cardio fitness variables.

Keywords

Cardio Vascular System -Respiratory System; Exhale Power Or Apacity; Resting Heart Rate; Household Wives; Hemoglobin Content; Maximum Oxygen Intake Capacity Of Lungs

Introduction

Man is a social animal with broad mind and with high thinking capacity and an un intruder in natural landscape. uncontrolled and Unprecedented population growth with unplanned industrialization around the globe have brought the manmade and natural environment into serious danger and conflict to set a degree that not only has degraded his sound, economic and social development but also destroyed the physical, social, moral, esthetics, and spiritual and over all well-being of man is jeopardized. The industrialized society is developing across road with enormous rate due to growing demand on the part of the population of the world . we all are aware about the fact that The human population of the world has increased and expended three folds in the past nine decades the consumption of fossil fuel has increased forty times and industrial pollution has increased by fifty five folds. Obviously this pattern cannot continue indefinitely what kind of industrial society we want. This is a matter of deep concern and has been an area of thinking today. The fact is that never before in the history man has ever faced such a huge crises of self-destruction as he faces today. The air water , pollution and bottom ash generated because considerable health problems, especially related to respiratoryhealth. Broke (2014) conducted his study on “Cardiovascular Effects Of Pollution”. The Air pollution is a mixture of poisonous gases, liquids and PM (particulate matter). So In the present rural and urban world, Particulate Matter is principally derived from burning of fossil fuel with individual constituents varying in size from a few nanometers to 10 micron in diameter. the ambient concentration, the pollution source and chemical composition may play vital roles in determining the biological toxicity and subsequent ill health effects. Nevertheless, studies from across the world have consistently shown that both short- and long-term exposures to PM are associated with a host of cardiovascular diseases, including myocardial is chaemia and infarctions, heart failure, arrhythmias, strokes and increased cardiovascular mortality.

Procedure And Methodology

For the present study a total of sixty 60 subjects were randomly selected 30 ashousehold wives and 30 as non-household wives of Kashmir division the data related to the different variables for which comparison between two groups was drawn has been separately collected for each variable for both the groups which include 30 subjects from non household wives zones and 30 from non household wives of Kashmir Division. The subjects were selected by simple random sampling method. The age of the subjects ranged between 25-40 years.

Equipments Used For Collection of Data
The various testing kits and equipments that were used for the collection of data pertaining to different respiratory cardio variables household wives the heamoglobin content of blood was measured by testing kit comprises of Haemometer,Hcl diluted water needle or syringe . the exhale capacity of lungs of both the groups was measured by an equipment called as Peak flow meter for measuring exhale capacity. For measuring resting heart rate per minute A digital Stop watch was used and for maximum oxygen intake capacity following equipments were used .Vo2max. Bench stopwatch metronome for cardiovascular endurance.

The various testing kits and equipments that were used for the collection of data pertaining to different respiratory cardio variables household wives the heamoglobin content of blood was measured by testing kit comprises of Haemometer,Hcl diluted water needle or syringe . the exhale capacity of lungs of both the groups was measured by an equipment called as Peak flow meter for measuring exhale capacity. For measuring resting heart rate per minute A digital Stop watch was used and for maximum oxygen intake capacity following equipments were used .Vo2max. Bench stopwatch metronome for cardiovascular endurance.

Results

Table 1: Haemoglobin Percentage between Household And non wives Inhabitants of Kashmir.

Group

Mean

S.D.

M.D.

D.F.

O.T.

T.T.

Non household wives

12.87

2.91

1.05

58

2.3

2

*Level of Significance = 0.05

Tabulated‘t’ 0.05 (48) = 2.00

Table-1 shows that that the mean difference between primary and secondary industrial inhabitants because the mean of both the group is 12. 87 and 11.82 respectively this indicates that mean of non-household is greater than household wives inhabitant group and their mean difference is 1.05.. It was also required to calculate the standard deviation of the data related to hemoglobin before applying T test for knowing portentous deviation or difference and the validation of hypothesis , standard deviation was calculated between non-household wives and household wives group which was estimated as 2.91 and 1.07 respectively. T test was used to compare the hemoglobin content of blood between two groups As the ‘t’test was applied it was found that there is portentous deviation or difference in the average hemoglobin content in blood between household and non household wives roup as the obtained value of calculated ‘t’ (2.30) was greater than tabulated ‘t’ (2.00) when level of significance was at 0.05which shows that there is a significant difference in hemoglobin content percentage between household wives andnon household wives group of Kashmir division.

Graph 1: Graph shows the of Mean or average Difference of Haemoglobin Percentage of household and non household wives.

 

Table 2: Exhale power or Capacity between secondary-Industrial and Primary-industrial Inhabitants of Kashmir.

Group

Mean

S.D.

M.D.

D.F.

O.T.

T.T.

Primary-industrial

449

64.39

51.6

58

2.77

2

*Level of Significance = 0.05

Tabulated‘t’ 0.05 (48) =2.00

Table-2 shows that that the mean difference of exhale capacity between primary and secondary industrial inhabitants because the mean of both the group is 449 and 397.4 respectively this indicates that mean of primary group is greater than secondary industrial inhabitant group and their mean difference is 51.6 It was also required to calculate the standard deviation of the data related to exhale capacity before applying T test for checking portentous deviation or difference and the validation of hypothesis , standard deviation was calculated between Primary-Industrial and Secondary Industrial group which was estimated as 64.39 and 64.92 respectively. T test was used to compare the exhale capacity between two groups As the ‘t’test was applied it was found that there is significant difference in exhale capacity between Secondary- industrial and Primary-industrial group as the obtained value of calculated ‘t’ (2.77) was greater than tabulated ‘t’ (2.00) when level of significance was at 0.05, which shows that there is a portentous difference in exhale power or capacity between Household ladies group and non-household wives group.

Graph 2: Graph that shows the average difference of exhaleCapacity of household and non-household wives of Kashmir.

Table 3: Resting Heart beat or pulse rate between Secondary Industrial and Primary Industrial Inhabitants.

Group

Mean

S.D.

M.D.

D.F.

O.T.

T.T.

Non-household wives

72.84

5.25

3.84

48

2.38

2

Level of Significance = 0.05

Tabulated‘t’ 0.05 (48) = 2.00

Table-2 shows that that the average deviation of resting heart beat or pulse rate between non-household and household wivesbecause the mean of both the group is 72.84 and 76.68 respectively this indicates that mean of Non household group is low which means that non household wives group has good resting heart rate than household wives group and there is a difference in the calculated average of resting heart beat and this difference is 3.84 It was also required to calculate the standard deviation of the data related to resting heart rate before applying T test for checking portentous deviation or difference and the validation of hypothesis , standard deviation was calculated between non household and Household which was estimated as 5.25 and 5.09 respectively. T test was used to compare the resting heart rate between two groups As the ‘t’test was applied it was found that there is portentous deviation in resting heart rate between Household industrial and non household wives group as the obtained value of calculated ‘t’ (2.38) was greater than tabulated ‘t’ (2.00) when level of significance was at 0.05, which shows that there is a significant difference in resting heart rate between household and non-household wives of Kashmiri Division.

Graph 3: Graphs shows of average deviation of Resting Heart Rate of Household and non-household wives of Kashmir.

 

Table 4: Maximum oxygen intake capacity Vo2 Max Household And non wives of Kashmir.

Group

Mean

S.D.

M.D.

D.F.

O.T.

T.T.

Non-household

65.7

5.52

7.42

58

2.5

2

Household

56.2

6.28

             

*Level of Significance = 0.05

Tabulated‘t’ 0.05 (58) = 2.00

Table-4 highlights that the average difference of max. oxygen intake capacity between non household and household wives because the mean of both the group is65.66 and 56.24 respectively this indicates that mean of non household group is greater than household group and their average difference is 8.42 It was also required to calculate the standard deviation of the data related to max. Oxygen intake capacity before applying T test for checking significance difference and the validation of hypothesis, standard deviation was calculated household andhousehold group which was estimated at 64.39 and 64.92 respectively. T test was used to compare the exhale capacity between two groups as the ‘t’test was applied it was found that there is portentous deviation in max. Oxygen intake capacity between household and non-household wives, as they obtained value of calculated ‘t’ (2.50) was greater than tabulated ‘t’ (2.00) when level of significancewas at 0.05, which shows that there is a portentous difference in max. Oxygen intake capacity between household and non-household wives group.

Graph 4: Graph -4 highlights the Mean deviation of Max oxygen intake capacity of Household and non wives of Kashmir.

Conclusion

Taken in to consideration analytic and scientific procedure of obtained data related to various variables of the discussed study the following conclusion was made. After statistical analysis and interpretation collected of data a enormous difference in the respiratory and cardio variables of household and non-household wives of Kashmiri. From result of this survey type of study that was conducted on household and non-household wives of Kashmiri Division. we arrived to this strong conclusion that the respiratory cardio system and variable related to respiratory cardio system of non-household wives showed good performance as compared to household wives because in all the four selected cardio respiratory variables the non-household wives group showed very low performance as compared to household wives - group this shows and indicates this all might be due to the presence of traditional chulas smoke pollution in household areas as compared to non-household group. Householdladiesmost commonly inhabitants of village likely get victimized and infected by the smoke pollutants that gets liberated from traditional chulas in the form of poisonous and harmful gases ashes carbon monoxide and other harmful chemicals. At last From this study we come this conclusion that household wives were poor in cardio respiratory variables as comparedto non-household wives- individual residing near them which results in the lowering the working capacities of different systems related to respiratory and cardio system These pollutants create lot of health related issues which degrade the health and working capability of individual and sometimes the life of whole population comes under danger. Hence it is concluded that household wives are poor in cardio respiratory capacities.

Recommendation

Taking into consideration the results of the conducted study, I am, strongly going for below discussed recommendations that are are made for the betterment of the society and the population for future generation and for practical applications:

  • It is strongly recommended same study should be conducted on rural and urban areas for comparison.
  • The government should go for free LPG plantation drive to in every district so that the smoke elimination from chulas will reduce level of pollutants gets minimized and should follow those modern techniques and methods by which emission of pollutants can be reduced to maximum and by providing protective gears to al l workers and inhabitants living in those areas so planet earth could be saved for future generation and for their existence.

References

  1. Ardie MC. Exercise Physiology, Philadelphia: Lea and Finger. 1999.
  2. “Effect Of Air Pollution And Racism On Ethnic Differences In Respiratory Health Among Adolescents Living In An Urban Environment”, Health Place. 2013; 23: 171-178
  3. Boor P. “Renal, Vascular And Cardiac Fibrosis In Rats Exposed To Passive Smoking And Industrial Dust Fibre Amosite”, Journal Of Cellular And Molecular Medicine.2009; 13: 2009.
  4. Gerard J. Tortora, Introduction to Human Body, United States: John Wiley and Sons Publishers, 2005.
  5. Binoda C. River Pollution in India, New Delhi: APH Publishing Corporation, 1995.